You can collect 5 data points for 1 dimension as this picture shown below.
1. Setup IPQC setting in the product management page and make sure to setup the dimension and cavity
2. Data collection
In your dimension checklist, you will need to maintain these values according to your dimension and cavity settings in IPQC.
You will need to set sequence of the questions from 1-5 (refer to red box), the sequence will determine the data will be shown in which row (N1 - N5).
Example: to show the data on N4, set the sequence as 4.
For multiple data points, make sure to have 5 questions with same Dimension and Cavity but different sequences.
After finish setting up the question, make sure you have attached the dimension checklist.
Then once you attach the dimension checklist, you will be able to see the data in Inquiry > IPQC as you do the IPQC